Charging Goodman Heat Pumps

Split System Heat Pumps
SSP-PRC001-EN Split System Heat Pumps Split System Heat Pumps 7 1/2 – 20 Tons – 60 Hz Air Handlers 5 – 20 Tons – 60 Hz … Retrieve Full Source

NSTALLATION -C OR ELF IR ONDITIONERS GPC/GPH “H” SERIES
Goodman Manufacturing Company, L.P. Heat pumps require special location consideration in areas of heavy snow accumulation and/or areas with prolonged continuous subfreezing temperatures. For charging in the warmer months, 10 … Retrieve Content

PowerPoint Presentation
READ REQUIRED SUPERHEAT TEMPERATURE AT CONDENSER ENTERING AIR DRY BULB TEMPERATURE ADD CHARGE TO LOWER SUPER HEAT REMOVE CHARGE TO RAISE SUPERHEAT USING SUPERHEAT Charging Two Stage Units The high stage pressure Goodman Other titles: Arial Batang Default Design … Access Full Source

Installation Operation Maintenance
If charging by weight, refer to refrigerant charges that are given in Table 3. If additional refrigerant is needed because All packaged and split system air conditioners and heat pumps have a rated capacity of less than 20 tons. … Access Content

CONDENSING UNIT © 2005-2012 Goodman Manufacturing Company, L …
Or, for Goodman ® brand products conditioners or heat pumps, to access a list of product pages If you must heat a cylinder for faster charging, partially immerse it in warm water. Never fill a cylinder more than 80% full of liquid re-frigerant. … Retrieve Full Source

PowerPoint Presentation
Evacuation / Charging Superheat and Subcooling Charging Methods 2007 Evacuation Moisture In A Refrigeration System Visible Moisture Water Droplets In Goodman’s case, Normal Subcooling Range: 9 to 13°F Subcooling for heat pumps units 14 to 18°F for straight cool units. Any … Doc Viewer

Installation And Operation – Heating Supply Company
(READ THE SLIDE) * (READ THE SLIDE) * Charging While Machine Is Running Charge (READ THE SLIDE) Understand that Goodman and Amana no longer use Capillary Tube metering Vacuum Pumps Pumps used with CFC and HCFC charged systems may also be used on R410A systems as long … Retrieve Doc

Draft Heat Pump Reference Guide – Oklahoma Electric …
Goodman Company • Rheem Manufacturing Subclass: Split systems Type: Ductless Hardware: Multizone or Mini-Split • Some heat pumps have economizer cycles that allow cool water to circulate through a water-to-air exchanger in the ductwork. … Fetch Doc

Table Of Contents
These heat pumps have been rated in the past by Air Conditioning and Refrigeration Institute (ARI). Since January 2000 the heat pumps have been rated by the Interna-tional Standards Organization (ISO), … Read Here

Superheat: The Best Way To Tune An Air Conditioning System
Some Heat Pumps with TXV's are set at 7 to 9-F Super Heat because they have Suction Line Accumulators to store any spill-over liquid, which Goodman Expanded Data: Charging by weight is accomplished using the quantity of refrigerant indicated on the Tech. Service Data Sheet and/or … Read Document

Residential Piping And Long Line Guideline – Guest Home Page
Staying withinthese guidelines and charging to a minimum of 10_F(5.6_C) subcooling will ensure Air conditioners and heat pumps have separate charts dueto oil return needs for heat pumps in heating mode. 4 Table 1 — Long Line Accessory Requirements … Fetch Content

APPLICATION DATA SHEET
Item on all heat pumps to avoid liquid flood back to the compressor when switching from heat to cooling, reversal before and after defrost and during low ambient heating operation. If applied incorrectly suction line accumulators can … Return Document